Driver for Integration/Interface Adapter CableThe Integration / Interface Adapter Cable works with the Computer Interface Cable (P/N 2200-150) allowing users to upload firmware to the instrument using the USB or to stream real-time digital (ASCII) data continuously using the RS232 plug. Either plug can be used to communicate and/or configure the instrument.
(Note: Due to the Computer Interface Cable’s wiring configuration, we do not recommend using it for serial data output without this adapter cable)
For more information on cabling for the C3, C6, and all Turner Designs instrumentation please refer to the
Cable Guides or contact
Technical Support.
-
Installation & Operating Instructions-
Drivers Required for Cable Installation
C3 and C6 Integrator FirmwareTurner Designs announces the release of a new version of our Integrator Firmware. This firmware is designed for use by customers that are integrating their C3 or C6 with an external datalogger, CTD or similar system. The Integrator Firmware is different from the standard C3/C6 firmware and has some features that users need to consider before installing:
1) Internal datalogging is
NOT possible with this version of firmware. The Integrator Firmware is intended for data output only.
2) The data output rate defined by this Integrator Firmware is 1 second and cannot be changed to reflect longer or shorter data output rates.
3) Once power is applied there is a 15 second delay before data output starts at a 1 second interval.
4) If the wiper is enabled, it will rotate the set number of rotations upon powering the instrument and every 5 minutes as long as power is continuously supplied.
5) Sleep mode is disabled; therefore as long as power is continuously supplied the instrument will continue to stream data at a 1 second interval.
Download Firmware•
Integrator Firmware Hex File - 2200-202-FW (0.031MB)
If you have any questions about whether this firmware is right for your application or other questions please contact
Technical Support.
Integrating with Campbell DataloggersTurner Designs and
Campbell Scientific worked together to help our customers easily integrate the C3 Submersible Fluorometer or C6 Multi-Sensor Platform with any of the CR800 or CR1000 series dataloggers. Simply follow the steps below to quickly get your datalogger set up and begin data logging:
1) Download the .txt file that pertains to your datalogger series (see links below)
2) Upload that file to your Campbell Datalogger
3) Run the program using your Campbell Datalogger
4) Enable the 'Data Output Ready Mode' on our instrument (this will allow streaming of ASCII data at the set sample interval)
5) Plug our instrument into the datalogger and watch data stream or capture data using your datalogger
(NOTE: Be sure to use the 'Integration Cable' or 'Integration/Interface Adapter Cable' to plug our C3 Submersible Fluorometer or C6 Multi-Sensor Platform into your datalogger; using the Standard Interface Cable may result in the loss of data or inability to communicate with your datalogger)
DownloadsFor CR800 Series Campbell Dataloggers:
C3_C6_Datalogging-CR8.zip (0.001MB)
For CR1000 Series Campbell Dataloggers:
C3_C6_Datalogging-CR1.zip (0.001MB)
If you have any questions about whether this firmware is right for your application or other questions please contact
Technical Support.
C3 Add-In Module for ArcGIS® 10.0 (for use with C-FINS package)To use the Add-In Module please do the following:
• Ensure ArcGIS® 10.0 is installed on your PC.
• Download the free
C3 Add-In Module (zip file) to your desktop.
• Unzip and open the file and click on the File TD_C3.esriAddIn
• This is a self-extracting file that will add the C3 Add-In Module to your ArcGis 10.0 system.
• Open the
C3 Add In Module Quick Start file (pdf) for information on using the Add-In Module
Please contact if you have questions.
C-Soft Firmware Upgrade & Software Download for C3 Submersible Fluorometer or C6 Multi-Sensor PlatformC-Soft Firmware Upgrade & Software Download for C3 Submersible Fluorometer or C6 Multi-Sensor Platform Firmware version 2.1 does not allow data output to continue when the instrument’s memory is full. We revised the current firmware and released version 2.2 allowing users to continue capturing data output even though the memory’s maximum capacity has been reached. We recommend all C3 and C6 users to upgrade to firmware version 2.2 enabling this feature and keeping up to date with the latest functions available for the C3 Submersible Fluorometer and C6 Multi-Sensor Platform.
Users who received their C3 Submersible Fluorometer or C6 Multi-Sensor Platform on or before 02/16/2011 should upgrade their instruments using the Firmware and Software upgrades below to maximize performance of their instrument.
Note: Upgrade is not required for customers using the C3 Submersible Fluorometer for the SMART protocol. Firmware Update •
Easy to download - firmware upload instructions •
TI Downloader Program (required for uploading firmware; 2.3MB)
•
C-Soft Hex File Version 2.2 (0.03MB)
C-Soft Software Download •
Easy to download - software installation instructions •
C-Soft Software Version 2.1 (90.8 MB)
Please contact if you have questions.