Safety Data Sheets (SDS)

Click the links below to view desired Safety Data Sheet.  To request pricing for any of the part numbers listed below click here

Acetone in chlorophyll standards
Part Numbers: 10-850
Shelf Life: 1-year un-opened stored in freezer at -20°C

Fluorescein Calibration Standard

Part Numbers: 10-506
Shelf Life: 1-year under ambient conditions

Fluorescein Dye
Part Numbers: 10-109
Shelf Life: 1-year under ambient conditions

PTSA Calibration Standard
Part Numbers: 10-608, 10-609
Shelf Life: 1-year under ambient conditions

Rhodamine WT Calibration Standard
Part Numbers: 6500-0206500-120, 6500-220
Shelf Life: 1-year under ambient conditions

Rhodamine WT Dye
Part Numbers: 10-108
Shelf Life: 1-year under ambient conditions

FAQs
Frequently Asked Questions

Below are general FAQs.  For instrument specific FAQs please visit individual product pages

  • When should I use my Shade Cap?
    We recommend use of the shade cap as it provides a fixed distance for sample measurement and minimizes affects from ambient light. The Shade Cap also offers protection for the optics and prevents damage from deploying, recovering, or transporting the instrument, in fast-flowing environments, and/or from bottoming out in shallow environments.
  • What preventative maintenance or care should always be done before deploying my C3?
    To protect your bulkhead connector from damage, a light coat of Silicone spray should be used on the rubber of the male pins of the bulkhead to aid in sealing. The manufacturer recommends 3M™ Silicone Lubricant Spray or Loctite 8021 spray. Note: You should avoid using silicone grease. DO NOT USE WD-40 - it will destroy the connectors.
  • Where can I purchase turbidity standards for the C3?
    AMCO/GFS has turbidity standards for use with the Cyclops. Standards can be purchased directly from GFS Chemicals utilizing the information below. Part Number 8506 - 10 NTU Standard for Turner Designs C series Part Number 8507 - 100 NTU Standard for Turner Designs C series Part Number 8619 - 20 NTU Standard for Turner Designs C series Part Number 8620 - 1000 NTU Standard for Turner Designs C series Part Number 8621 - 3000 NTU Standard for Turner Designs C series GFS Chemicals, Inc. 3041 Home Road Powell, OH 43065 Phone: 877-534-0795 (U.S. and Canada)
  • Why can't I enable ASCII data output from my C3?
    Here are some common reasons why ASCII data output will not enable: The firmware version you are using does not support ASCII data output (must be 2.00 or greater). Your COM port is not correctly configured or properly working. You've established a connection at a baud rate other than 9600 (must be 9600 to enable ASCII data output). You have not cycled the unit's power after connecting to HyperTerminal or other Terminal program. You have not enabled ASCII data output using C-Soft.
  • How do I enable ASCII data output from my C3?
    There is a specific series of steps that needs to be followed in order to enable ASCII data output from a C3 or C6P instrument: You must begin C-Soft, establish a connection between your instrument and computer. Follow instructions in the User’s Manual on how to set up datalogging for your instrument. Once datalogging has been set up and enabled, C-Soft will automatically shut down, right after C-Soft closes you must disconnect power from the instrument. With the power disconnected and the C-Soft program shut down you must follow instructions on how to set up a HyperTerminal connection. Once HyperTerminal is set up and a connection has been established with your computer, connect the power to the instrument and wait at least a minute and a half or the predetermined time that was set during datalog set up for data to begin scrolling at your set sampling interval.
  • I am having trouble getting C-Soft to initialize when opening it, what should I do?"
    First make sure that your firmware and C-Soft software are updated. The most current versions of the software and firmware are available from the Turner Designs website. Once you have confirmed and/or installed the most current version, disconnect all connections made thus far, close the C-Soft program if it is open and follow the procedure below: Connect the 8 pin female end of the interface cable to your instrument’s 8 pin male end connector. Connect the interface cable’s serial plug to your computer or laptop. Note: Make sure you know what COM port you are plugging in to so the correct COM port can be selected in the C-Soft program. Begin the C-Soft program and select the COM port you are currently plugged in to using the pull down menu. Supply power to the instrument using the 12 volt power supply provided. Approximately 1-2 seconds after supplying power to the instrument, you should see the LED flash on for about 2 seconds and then turn off (NOTE: If you have a turbidity sensor you will not see an LED flash for that sensor and if you have UV sensors you will need to hold a white piece of paper in front of the sensor head to see the blue light on the paper indicating the LED is working. All other sensor LEDs are visible.) If you see LEDs flash as described, go to the next step. Wait a minimum of 10 minutes for a blue scrolling bar to appear indicating the initialization of the software. Note: The software will take about 13 seconds or less to initialize if there are no data stored in memory. However, the software may take up to 10 minutes to initialize if the memory is full. If the initialization process has not begun after 10 minutes, disconnect the power supply, wait 10 seconds, then reconnect the power supply and wait for initialization. If C-Soft will not initialize, contact Turner Designs’ technical support or (408) 212-4067
  • I am planning on deploying my C3 with the submersible battery. How many readings will I get?
    Use our Battery Life Calculator to estimate the submersible battery life based on the sample interval of the C3.
  • I purchased a pigtail cable with my C3, how does it need to be wired?"
    Wiring diagrams for the pigtail cables are available in the Cable Guide.
  • Where can I find instructions on how to use the Solid Secondary Standard with my C3?
    Instructions on how to use the Solid Secondary Standard are available at http://docs.turnerdesigns.com/t2/doc/instructions/998-2311.pdf
  • Do I need to do anything special to the C3 cables and connectors?
    The bulkhead connectors for the C3 require maintenance and lubrication to ensure that they don’t degrade and cause the unit to take on water (leak). Mating surfaces of the connectors need to be lubricated on a regular basis with 3M™ Silicone Lubricant Spray, Loctite 8021 spray or equivalent. You should avoid using silicone grease. DO NOT USE WD-40 - it will destroy the connectors. Other things to remember: Avoid nicks and cuts around contacts as these are the sealing surfaces. Neoprene can be seriously degraded if exposed to direct sunlight or high ozone levels for extended periods of time. Avoid sharp bends at cable entry to connector. If you have any questions regarding maintenance of connectors, please contact Technical Support
  • Will the CR800 and CR1000 Campbell Scientific Software work with the CR6?
    Unfortunately, the software that Campbell Scientific creates would not be compatible with their different versions. Our recommendation is to reach out to the Campbell Scientific Datalogger Support team and get instructions on how to setup up analog and ASCII data strings on their newer devices.
Videos
Videos

CyanoFluor in the Field with Dr. Alan Wilson

CyanoFluor in the Field with Dr. Alan Wilson
Search video...
CyanoFluor in the Field with Dr. Alan Wilson

CyanoFluor in the Field with Dr. Alan Wilson

12:09
Play Video
What is PhytoFind?

What is PhytoFind?

01:44
Play Video
How to calibrate the FluoroSense Handheld Fluorometer

How to calibrate the FluoroSense Handheld Fluorometer

01:40
Play Video
AquaFlash: What is Active Fluorescence

AquaFlash: What is Active Fluorescence

02:50
Play Video
AquaFlash: Package & Accessories

AquaFlash: Package & Accessories

01:05
Play Video
AquaFlash: Factory Calibration Check

AquaFlash: Factory Calibration Check

01:26
Play Video
AquaFlash: Resetting to Factory Calibration

AquaFlash: Resetting to Factory Calibration

02:49
Play Video
AquaFlash: How to measure a sample using the AquaFlash

AquaFlash: How to measure a sample using the AquaFlash

02:10
Play Video
Data Downloading

Data Downloading

03:09
Play Video
CyanoFluor: Predicting HAB events

CyanoFluor: Predicting HAB events

01:38
Play Video
CyanoFluor: Field Kit Overview

CyanoFluor: Field Kit Overview

01:14
Play Video
CyanoFluor: How to measure a sample

CyanoFluor: How to measure a sample

02:24
Play Video
Ballast-Check 2: Setting Ship and Tank Values

Ballast-Check 2: Setting Ship and Tank Values

00:56
Play Video
CyanoFluor: How to measure PC to CHL ratios in DOM rich water

CyanoFluor: How to measure PC to CHL ratios in DOM rich water

03:05
Play Video
Ballast-Check 2: What's in the box

Ballast-Check 2: What's in the box

02:05
Play Video
CyanoFluor: How to verify calibration using the calibration check standard

CyanoFluor: How to verify calibration using the calibration check standard

01:35
Play Video
Ballast-Check 2: Measuring a sample - LOW risk reading

Ballast-Check 2: Measuring a sample - LOW risk reading

02:49
Play Video
Ballast-Check 2: Measuring a sample - HIGH risk reading

Ballast-Check 2: Measuring a sample - HIGH risk reading

02:59
Play Video
Ballast-Check 2: Filter Washing

Ballast-Check 2: Filter Washing

01:25
Play Video
Ballast-Check 2: Data Download

Ballast-Check 2: Data Download

03:12
Play Video
Ballast-Check 2: Using the Calibration Check Standard

Ballast-Check 2: Using the Calibration Check Standard

01:48
Play Video
Fluorometer calibration with liquid primary standards

Fluorometer calibration with liquid primary standards

04:54
Play Video
Using A Fluorometer To Detect Optic Brighteners In Water Quality Samples.avi

Using A Fluorometer To Detect Optic Brighteners In Water Quality Samples.avi

08:26
Play Video
Lightweight, water-tight and easy-to-use field fluorometer

Lightweight, water-tight and easy-to-use field fluorometer

00:37
Play Video